Print this page

PINCHER TEST

An alternative for the Randall-Selitto test

Description
Key features
Specs
How to order

Description

Bioseb's "Rodent Pincher" algometer allows calibrated forceps to induce quantifiable mechanical stimulation in the animal (rats or mice) on a linear scale. The most suitable protocol was experimented by determining the effects of 3 repetitive measurements on the 2 hindpaws, respectively over long-term (9 days), mid-term (1 day) and short-term (2 hours). It was primarily developed as an analgesimeter/algometer (analgesia measurement instrument) for nociceptive tests. In this specific use, the Rodents Pincher not only represents an alternative to the "RANDALL & SELITTO" test - but also presents the following advantages when compared to the classical test:

  • More ethical handling, less stressful for the animal (rat or mouse) resulting in less variable measurements
  • Faster measurement, less traumatic for the tissues
  • Digital measurement with metrological traceability 

Furthermore, this pincher-based analgesia meter can also be used for other applications that require a controlled force or pressures values, for example :

  • Sensitivity recovery after nerve crush: pinching is applied at several places over the paw to see the sensitivity recovery
  • Mechanical injuries for thrombotic models
  • Mechanical stimulation for in vivo electrophysiological recordings using the possibility to trigger recording on force thresholds

Comparative studies (including comparative tests with the Randall & Sellito analgesimeter) have demonstrated the accuracy of this pincher-based algometer for easy, fast and reproducible measurement of mechanical pain threshold on rat limbs. Moreover, it allowed to perform rat analagesia testing with minimal constraint, which reduces data variability.

Operating principle

The pressure is applied in the "inter-digital" region. When used on the rat the pressure can also be applied to the tail. The instrument displays the force (in grams, newton, oz, lbs) at which the animal reacts and reports the nociception threshold. 

Individual pain threshold measurements (up to 100) are stored in the internal memory, and can be downloaded post experiment. Recently an embedded statistical computation has been included in the electronic device of the algometer. This is a very useful feature that has been very well received and used by users of large numbers of tests. The display shows in real time the mean, standard deviation and variation coefficient from groups of animals (rats or mice). This feature also allows the user to cancel any analgesia test incorrectly performed.

 

Specs

Animal

Rat or mouse (2 different pinchers)

Measuring Range

0 to 2000 grams

Units

Grams / newtons

Resolution

0,1 gram or 0,001 N

Results

Displays the current applied force and the maximum applied force during the test

Statistic

Mean, standard deviation and variation coefficient

Power supply

Battery powered, this instrument is autonomous.
Possibility of using a 220V/110V 50hz/60hz adapter.

Data output

RS232 for PC or printer

EMC

Controlled

How to order

Pincher test

BSBIORPR

76-0738

Pincher test for rat

BSBIORPM

76-0737

Pincher test for mice

BSBIOCIS

76-0741

BIO-CIS Software, incl. RS232/USB cable

How to order

Please contact our local delegates or contact us directly for receiving a quote.

 

Key features

  • More ethical handling, less stressful for the animal (rat or mouse) resulting in less variable measurements
  • Faster measurement, less traumatic for the tissues
  • Digital measurement with metrological traceability